MPTroubleshooter seems to be case sensitive when it comes to the name of the site system during Post-Installation check, not sure if this began after W2003 SP1 was applied or maybe I have never run it agains this one.
I could not find any problems with the MP it self, it was providing policies and processing incoming data
The errors returned were actually not true.
"All MPs listed in SQL do not match the return of the MPlist query" which was not true when comparing http://server/sms_mp/.sms_aut?mplist the list returned from this MP against the one on a secondary child that was not failing in the MPTroubleshooter.
The MPTroubleshooter also stated that the MP was not in the SMS_SiteSystemToSQLConnection_<site> group of the site server which was also untrue.
The MP had been created as a site system in SMS using lower case in the name which was different from all the others not showing any errors when tested. Recreating the system DSN on the MP system to match the case did not help, only by removing the MP and recreating using upper case letters in the name resolved the issue.
Posted
Apr 20 2007, 09:18 AM
by
Larus Milan Bulat